SV-46 II "Flying Fox" External Dock Shutdown Checklist
By Super Chief Daryl F. Gates
Shutdown checklist for an Externally Docked SV-46 II. This checklist assumes you are in an externally docked state, and completed all steps necessary to do so.
   
Award
Favorite
Favorited
Unfavorite
MTS Shutdown
  • MTS ICH COUPLER - DISABLED
  • MTS HELICON COUPLER - DISABLED
  • MTS SPRCON COVER - OPEN
    a. MTS SPRCON - DISABLED
    b. MTS SPRCON COVER - CLOSE
  • MTS PROP INJECTOR - DISABLED
  • MTS SYS POWER COVER - OPEN
    a. MTS SYS POWER - DISABLED
    b. MTS SYS POWER COVER - CLOSED
MES Shutdown
  • MES 2 HVVFM COVER - OPEN
    a. MES 2 HVVFM - DISABLED
    b. MES 2 HVVFM COVER - CLOSE
  • MES SYS 2 POWER COVER - OPEN
    a. MES SYS 2 POWER - DISABLED
    b. MES SYS 2 POWER COVER- CLOSE
  • MES 1 HVVFM COVER - OPEN
    a. MES 1 HVVFM - DISABLED
    b. MES 1 HVVFM COVER - CLOSE
  • MES SYS 1 POWER COVER - OPEN
    a. MES SYS 1 POWER - DISABLED
    b. MES SYS 1 POWER COVER- CLOSE
NAS Shutdown
  • N/A SYS POWER COVER - OPEN
    a. N/A SYS POWER - DISABLE
    b. N/A SYS POWER COVER - CLOSE
FCS Shutdown
  • EXT POWER - IN USE
  • FCS KNOB - FCS 2
  • FCS PURGE CONTAM - DISABLED
  • FCS FUEL CELL 2 COVER - OPEN
    a. FUEL CELL 2 - DISABLED
    b. FUEL CELL 2 COVER - CLOSE
  • FCS KNOB - FCS 1
  • FCS PURGE CONTAM - DISABLED
  • FCS FUEL CELL 1 COVER - OPEN
    a. FUEL CELL 1 - DISABLED
    b. FUEL CELL 1 COVER - CLOSE
LENR Pre-Shutdown
  • BATT KNOB - BATT 2
  • CHARGE ALLOW - DISABLED
  • BATT KNOB - BATT 1
  • CHARGE ALLOW - DISABLED
  • MAIN SYS BUS 1 - DISABLED
  • MAIN SYS BUS 2 - DISABLED
  • MAIN TO UTIL BUS - DISABLED
  • LENR FUSE ALLOW - DISABLED
  • VERIFY LENR CORE TEMP DROP
  • VERIFY LENR POWER OUTPUT ZERO (0)
  • VERIFY LENR 'FUSING' NO LONGER DISPLAYED
  • LENR CORE HEATER - DISABLE
RCM Shutdown
  • RCM TANK 4 BLADDER - DEPR'D
  • RCM TANK 3 BLADDER - DEPR'D
  • RCM TANK 2 BLADDER - DEPR'D
  • RCM TANK 1 BLADDER - DEPR'D
  • RCM KNOB - ROTATE TO EACH TANK
    a. VERIFY DEPRESSURIZATION
    b. PROCEED TO NEXT STEP WHEN ALL TANK <5psi
  • RCM SYS POWER COVER - OPEN
    a. RCM SYS POWER - DISABLED
    b. RCM SYS POWER COVER - CLOSE
  • FAULT ACK - ACKNOWLEDGE
VMS Shutdown
  • VMS DISPLAY:SYSTEM POWER SET - DISABLED
LENR Shutdown
  • VERIFY MINIMUM SAFE SHUTDOWN TEMP
  • LENR SYS POWER COVER - OPEN
    a. LENR SYS POWER - DISABLED
    b. LENR SYS POWER COVER - CLOSE
COMM Shutdown
  • COMM XMTR POWER - DISABLED
  • COMM SYS POWER COVER - OPEN
    a. COMM SYS POWER - DISABLED
    b. COMM SYS POWER COVER - CLOSE
TMS Shutdown
  • TMS KNOB - LOOP 2
  • TMS CL RBLC POWER - DISABLED
  • TMS CL CIRC PUMP SPD - LOW
  • TMS CL TANK BLADDER - DEPR'D
  • VERIFY CL DEPRESSURIZING
  • VERIFY CL TANK RISING
  • TMS KNOB - LOOP 1
  • TMS CL RBLC POWER - DISABLED
  • TMS CL CIRC PUMP SPD - LOW
  • TMS CL TANK BLADDER - DEPR'D
  • VERIFY CL DEPRESSURIZING
  • VERIFY CL TANK RISING
  • TMS TM SYS COVER - OPEN
    a. TM SYS - DISABLED
    b. TM SYS COVER - CLOSE
CSSM Shutdown
  • BATT KNOB - 2
  • BATT TO SYS BUS 2 - DISABLED
  • BATT 2 COVER - OPEN
    a. BATT 2 - DISABLED
    b. BATT 2 COVER - DISABLED
  • BATT KNOB - 1
  • EXT POWER - CUT OFF
  • BATT TO SYS BUS 1 - DISABLED
  • BATT 1 COVER - OPEN
    a. BATT 1 - DISABLED
    b. BATT 1 COVER - DISABLED
  • DISABLE ALL LIGHTING