Stationeers

Stationeers

Not enough ratings
Precision Gas Mixer H2_N20
   
Award
Favorite
Favorited
Unfavorite
File Size
Posted
Updated
142.408 KB
29 Dec, 2023 @ 10:03am
26 Jan, 2024 @ 6:25am
2 Change Notes ( view )

Subscribe to download
Precision Gas Mixer H2_N20

Description
This fully automatic gas mixer gets around temperature differentials by using 2 volume pumps instead of a gas mixer. This will ensure a correct mix of fuel regardless of temperature variance in your gases. The script will automatically keep your fuel tank(s) topped up and will prevent over pressurisation. You do not need to adjust any settings on the volume pumps as the script takes care of that for you. Simply set your pins on the IC housing and turn it on!

You will need 1 Pipe Analyser and 2 Volume Pumps.

​If you require a precision gas mixer for H2/O2, you can find that here: https://gtm.steamproxy.vip/sharedfiles/filedetails/?id=3126014105
Popular Discussions View All (1)
2
29 May, 2024 @ 9:54pm
Temperature
Saboteur58
3 Comments
Golden Dragon 2 Sep, 2024 @ 6:01pm 
Works fine, but I try to awoid condensating N2O after mixer, so I decreased settings 10 times.
It's fine for combustion centrifuge.
Golden Dragon 28 Aug, 2024 @ 8:49am 
Okay, the problem is the liquid phase of the nitrous oxide. The mixer counts it as part of the gas, but the centrifuge doesn't use it, it just throws it into the exhaust. So there's no point in counting the liquid phase in the mix if you burn the finished mix straight away.

Just do an additional nitrous oxide rarefaction step to avoid the liquid phase in the mixer.
Golden Dragon 28 Aug, 2024 @ 8:39am 
Cant get it to work.
With default setings It tries to blast pipes, by reaching pressure over pipes limit
If I decrease pressure in code, it make uneffective mix with 70% nos and 30% volatiles, ignoring 50\50.